PoE Standards Reference

IEEE 802.3af, 802.3at, and 802.3bt Power over Ethernet standards. The table shows the power sourcing equipment (PSE) output, the powered device (PD) input after cable loss, the maximum current per pair, and the minimum cable grade.

Built by a network engineerCalculations run locally in your browserNo signup requiredNetwork information is not transmitted to our servers

PoE Types (PSE → PD)

PSE output is the power the switch or injector delivers at its port. PD input is the guaranteed power available to the device after worst-case cable loss (100 m of cable). The difference is dissipated as heat in the cable.

StandardNameTypePSE OutputPD InputMax CurrentMin Cable
802.3afPoEType 115.4 W12.95 W350 mACat5e+
802.3atPoE+Type 230 W25.5 W600 mACat5e+
802.3bt (Type 3)PoE++Type 360 W51 W960 mACat5e+
802.3bt (Type 4)PoE++Type 490 W71.3 W960 mACat5e+

PoE Classification

Classification lets the PSE negotiate the right amount of power. Physical-layer classification uses a signature resistance; data-layer (LLDP) classification allows dynamic allocation. Classes 5–8 are defined in 802.3bt.

ClassStandardPSE MinPSE MaxPD MinPD Max
0802.3af15.4 W15.4 W0.44 W12.95 W
1802.3af4.0 W4.0 W0.44 W3.84 W
2802.3af7.0 W7.0 W3.84 W6.49 W
3802.3af15.4 W15.4 W6.49 W12.95 W
4802.3at30 W30 W12.95 W25.5 W
5802.3bt45 W45 W40 W40 W
6802.3bt60 W60 W51 W51 W
7802.3bt75 W75 W60 W60 W
8802.3bt90 W90 W71 W71.3 W

Pair Usage

  • 802.3af / 802.3at (Type 1 & 2): power delivered over 2 pairs (either 1/2 & 3/6 or 4/5 & 7/8). Mode A uses data pairs; Mode B uses spare pairs.
  • 802.3bt (Type 3 & 4): power delivered over all 4 pairs simultaneously, increasing available power and improving efficiency.